TSA AM270

Audio and visual alarm for portal monitors.
Easy Integration into Current Systems
Drogrammable Controller
Cost Effective

The TSA AM27O is a remote alarms monitor used with Rapiscan radiation detection pedestrian and vehicle portal monitors. The AM27O provides both audible and visual alarm indications for radiation alarms, low and high background alarms, and tamper conditions. Parallel relay outputs are provided to permit interfacing with existing alarm systems. The AM27O may be located up to 650 ft (200 m) from the farthest pillar to be monitored.

A test button is provided to check the operation of the lamp(s) and audio circuits. An acknowledge button silences the audio and clears the lamp(s). If the alarm is not acknowledged, the lamp(s) will follow the system’s status. The AM27O operates from an internal battery which is continuously charged from the ac line. If ac power is lost, the battery will provide more than 24 hours of continued operation. One AM27O will monitor two systems or two SC77O controllers. The AM27O is controlled by a programmable logic device. This allows the flexibility to provide custom operation for special applications.

Controls and Indicators:
- Four lamps per pillar
- Power LED
- SONALERT audio annunciator
- Internal jumper selects either blinking or steady lamps
- Lamp test and alarm acknowledge switches
- Key switch is provided to disable the audio alarm

Specifications

Display 4 alarm indicator lamps (LEDs) per pillar being monitored; one systems ready LED, one power on LED
Power Requirements 90 — 250 Vac, 47 — 63 Hz, less than 50 VA provides power to charge the internal, 12 volt, 7Ah sealed lead—acid battery pack
Battery Operation More than 24 hours of normal operation
Dimensions 7.5 h x 8.375 W X 8 d in. (19 X 21.3 X 20.3c m)
Weight ~15 lb (6.8 kg)
Environmental —30° to l20°F (-34° to 50°C), designed for use in a sheltered area


Features

Controls Momentary contact alarm acknowledge switch, key lock switch, and lamp test switch
Connections Power: Standard, three pin, U.S.1l5Vac power connector Input: One 4 pin, quick connect type terminal strip per system Output: One 12 pin, quick connect type terminal strip
Output Relay Contacts Maximum 0.6 amp at l2OVac